2011-02-24YR2681 – fourniture de 5 tables élévatrices (EDF)
Dans le cadre du projet de construction de la tranche tête de série EPR (European Pressurized Reactor) sur le site de Flamanville, le contrat YR2681 concerne la fourniture de 5 tables élévatrices:
— 4 tables de capacité de levage 2 tonnes, 1 500 x 1 000 pour le bâtiment HR avec forte contrainte d’installation. Ces tables se situent en zone rouge,
— 1 table de capacité de levage 5 tonnes, 2 000 x 27 000 pour le bâtiment HL.
Les prestations comprennent:
— Les études,
— La construction en usine …
Voir la passation de marché »
2011-02-12Maintenance matérielle et logicielle du parc des machines applicatives (architectures X86, Power, SPARC etc...)... (EDF)
Maintenance matérielle et logicielle des machines applicatives multi-marques (Power, SPARC, X86) multi-sites et des périphériques associés.
Le parc actuel représente environ 6 800 machines.
La maintenance matérielle recouvre:
— L’entretien, la réparation et la garantie de bon fonctionnement,
— Les déménagements de matériels.
Elle inclut les prestations de main d’œuvre, les déplacements et les pièces détachées.
La maintenance logicielle concerne les logiciels de base (système d’exploitation) et les …
Voir la passation de marché »
2011-02-07Fourniture de réservoirs cryogéniques (azote liquide) de forme horizontale (capacité: 10 m³) pour les centrales nucléaires (EDF)
Les principales caractéristiques techniques des réservoirs sont les suivantes:
— 31 réservoirs cryogéniques horizontaux de 10 m³,
— enveloppe externe renforcée (les alliages au nickel sont proscrits pour l’enveloppe extérieure),
— organes de sécurité renforcés (exemple: doublage des soupapes et disques de rupture d’expansion),
— contrôles renforcés lors de la fabrication (exemple: contrôle renforcé des tôles et des soudures).
La prestation comprend également:
— une phase de mise au point techniques …
Voir la passation de marché »
2011-02-01UK/PE 6671. Control valves (EDF)
The scope of works for the referenced contracts includes the following steps:design and manufacturing studies, procurement, manufacturing, quality controls and tests made at workshop, delivery on site.
The valves to be designed and manufactured under the contract UK/PE 6671 are control valves.
The classification of the valves means that the valves are important for the safety of the nuclear power plant. This safety classification leads to strong requirements on design, manufacturing and controls done on …
Voir la passation de marché »
2011-02-01UK/PE 6631. Classified butterfly valves (EDF)
The scope of works for the referenced contracts includes the following steps:design and manufacturing studies, procurement, manufacturing, quality controls and tests made at workshop, delivery on site.
The valves to be designed and manufactured under the contract UK/PE 6631 are classified butterfly valves.
The classification of the valves means that the valves are important for the safety of the nuclear power plant. This safety classification leads to strong requirements on design, manufacturing and …
Voir la passation de marché »
2011-02-01UK/PE 6501. Non classified valves and check valves (EDF)
The scope of works for the referenced contracts includes the following steps: design and manufacturing studies, procurement, manufacturing, quality controls and tests made at workshop, delivery on site.
The valves to be designed and manufactured under the contract UK/PE 6501 are non classified valves and check valves.
Further information and details are filled in the Appendix A of the PQQ.
Voir la passation de marché »
2011-01-24Fourniture et production d'air comprimé pour les épreuves enceintes de confinement lors des arrêts des tranches... (EDF)
Dans le cadre des épreuves enceintes de confinement des centrales nucléaires de production d'électricité, le candidat assure la fourniture, l’installation et la production d'air comprimé exempt d’huile, desséché et filtré, qualifié d’air respirable conformément aux exigences du décret 90.2777 du 28.3.1990 et de ses arrêtés pour gonfler le bâtiment réacteur (BR). L'installation, suivant le palier, assurera la production de 47 500 m³ à 81 440 m³ d'air comprimé qualifié respirable. La production d’air doit …
Voir la passation de marché »